Product Details:

Place of Origin: Guangdong, China
Brand Name: Quarrz
Certification: CE,FCC,ISO
Model Number: AU-300WG

Payment & Shipping Terms:

Minimum Order Quantity: 1 set
Price: USD399 to USD1299
Packaging Details: 45*20*36cm;4.5kg
Delivery Time: 3-7 days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 300 sets per month
Contact Now
Detailed Product Description
Modulus Resolution: 0.1M Modulus Range: 0.1~100.0M
Baume Resolution: 0.01°Bé Density Resolution: 0.001 G/cm3

Sodium Silicate Modulus and Density Tester, Baume Liquid Tester, Liquid Measuring Instruments AU-300WG


 

Application:

light industry,textile industry,foundry industry,refractory materials,papermaking,fine ceramics,civil engineering,chemical engineering system,mechanical industry,building industry,agriculture,cleaning industry.,etc.

 

In accordance with GB/T4029-2008 standards,the series products according to Archimedes principle buoyancy method.it is the new type sodium silicate modulus and density tester that has been researched and produced by Quarrz.density SG,modulus M,baume Bé can be tested accurately and quickly.

 

Sodium silicate is the common name for compounds with the formula Na2(SiO2)nO. A well known member of this series is sodium metasilicate, Na2SiO3. Also known as waterglass or liquid glass, these materials are available in aqueous solution and in solid form. The pure compositions are colourless or white, but commercial samples are often greenish or blue owing to the presence of iron-containing impurities. The modulus M of sodium silicate is determined by the proportioning of quartz sand and alkaline, i.e. molar ratio of SiO2 and Na2O, modulus that displays the composition of sodium silicate is one of important parameter, and is commonly between 1.5 and 3.5. The larger the modulus is, and the more difficult the solid sodium silicate solves in water. the content of water glass in water solution is indicated by density or baume.Viscosity of water glass is closely related to modulus,concentration and temperature.

 

 

Technical Parameter:

(1) AU-300WG modulus resolution:0.1M,baume resolution:0.01Bé ,density

resolution:0.001g/cm3

 

(2)AU-120WG modulus resolution:0.01M,baume resolution:0.001Bé,density

resolution:0.0001g/cm3

 

 

Features:

Density,modulus,baume can be read directly.

High precision,simple operation,stability and durability.

Dynamic measuring,density value can be updated along with liquid formula.

Function of water temperature setting and air buoyancy density compensation setting.

Function of buzzer warning and overload warning.

Including RS-232C interface.it is convenient to connect PC with printer.AU-40 can be chose to print data.

Equiped with special windproof dustproof cover,convenient structure,sturdy and durable.

Volatile liquid,corrosive liquid,viscous liquid,strong acid and strong base liquid can be measured quickly(relative accessories is available)

 

 

Measuring Procedure:

(1)Place beaker filled with sample on testing board.and deduct weight of pothhook.

(2)Make standard weight hanged on the pothpook and submerged into liquid to be tested.Density value,modulus,baume will be displayed.

 

 

Technical Specification:

Brand Quarrz
Item/Model AU-300WG AU-120WG
Modulus resolution 0.1M 0.01M
Modulus range 0.1~100.0M 0.01~100.00M
Baume resolution 0.01°Bé 0.001°Bé
Baume range 0.01~100.00°Bé 0.001~100.000°Bé
Density resolution 0.001 g/cm3 0.0001 g/cm3
Density range 0.001—99.999g/cm3 0.0001—99.9999g/cm3
Measuring model 3 group liquid measuring mold be provided at the same time.can work with different standard weight
Measuring time Around 3 seconds
Measuring method Dynamic measuring,density value can be updated along with liquid formula.
Result display Density,modulus,Baume
Specific gravity measuring accessories Aluminum alloy specific gravity shelf,aluminum alloy measuring board
Function setting Water temperature setting,water density setting,standard measuring weights weight value and weight vaule in water setting
Measuring principle Archimedes principle displacement method
Measuring result verification method Distilled water verification
Output method RS-232C standard communication interface,which is convenient to output and print data
Standard accessories

host,measurement plate,DE-20A standard liquid measuring

assembly,tweezer,thermometer,100g weight,windproof dustproof

cover,measurement support,power transformer

AU-20A standard liquid measurement assembly:

two pcs of stainless steel pothpooks,two pcs of normal glass weight,one pcs of standard stainless steel weight,two pcs of beakers.

Optional accessories

AU-40 printer,AU-20B anti corrosive liquid measurement assembly,AU-20A

standard liquid measurement assembly

Power supply AC100V~240V 50HZ/60HZ European standard
Packing size Length42.5 cm X width 17.5 cm X height32.5cm

 
 
Sodium Silicate Modulus and Density Tester, Baume Liquid Tester, Liquid Measuring Instruments AU-300WG