DSC for Curing and Melt Test with 0.01mW DSC Sensitivity and 0.1C Temperature Control DH-DSC-530LN

DSC for Curing and Melt Test with 0.01mW DSC Sensitivity and 0.1C Temperature Control DH-DSC-530LN

    • DSC for Curing and Melt Test with 0.01mW DSC Sensitivity and 0.1C Temperature Control DH-DSC-530LN
    • DSC for Curing and Melt Test with 0.01mW DSC Sensitivity and 0.1C Temperature Control DH-DSC-530LN
  • DSC for Curing and Melt Test with 0.01mW DSC Sensitivity and 0.1C Temperature Control DH-DSC-530LN

    Product Details:

    Place of Origin: China
    Brand Name: DahoMeter
    Certification: FCC,CE
    Model Number: DH-DSC-530LN

    Payment & Shipping Terms:

    Minimum Order Quantity: one set
    Price: Negotiable
    Packaging Details: standard exporting wooden package
    Delivery Time: In stock
    Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram,paypal
    Supply Ability: 300 sets per month
    Contact Now
    Detailed Product Description
    Usage: Differential Scanning Calorimeter Temperature Range: -150~500℃(Determine The Minimum Temperature Based On The Refrigeration Equipment)
    Heating Rate: 0.1~100℃/min Working Power Supply: AC220V/50Hz Or Customized
    Gas Pressure: 0.2MPa Constant Temperature Time: Recommended <24h

     

    Differential scanning calorimeter DH-DSC-530LN

    DSC for Curing and Melt Test with 0.01mW DSC Sensitivity and 0.1C Temperature Control DH-DSC-530LNDSC for Curing and Melt Test with 0.01mW DSC Sensitivity and 0.1C Temperature Control DH-DSC-530LN

    Introduction:

    Differential scanning calorimeter is a touch screen type, which can perform glass transition temperature test, phase transition test, melting and enthalpy value test, product stability, and oxidation induction period test.

     

    Standards:

    GB/T 19466.2-2004/ISO 11357-2:1999 Part 2: Determination of glass transition temperature

    GB/T 19466.3-2004/ISO 11357-3:1999 Part 3: Determination of melting and crystallization temperature and enthalpy

    GB/T 19466.6-2009/ISO 11357-3:1999 Part 6: Determination of Oxidation Induction Time and Oxidation Induction Temperature

     

    Technical parameters:

    1. Temperature range: -150~500℃(Determine the minimum temperature based on the refrigeration equipment)

    2. Temperature resolution: 0.01℃

    3. Temperature fluctuation: ±0.1℃

    4. Temperature repeatability: ±0.1℃

    5. Heating rate: 0.1~100℃/min

    6. Constant temperature time: recommended <24h

    7. Temperature control method: heating, constant temperature (automatic program control)

    8. DSC range: 0~±600mW

    9. DSC resolution: 0.01mW

    10.DSC sensitivity: 0.01mW

    11. Working power supply: AC220V/50Hz or customized

    12. Atmosphere control gas: nitrogen, oxygen (automatic switching of the instrument)

    13. Gas flow: 0-300mL/min

    14. Gas pressure: 0.2MPa

    15. Display mode: 8-inch LCD touch screen display

    16. Data interface: standard USB interface

    17. Parameter standard: Equipped with standard substances (indium, tin, zinc), users can calibrate the temperature by themselves

     

    Features:

    1. The industrial-grade 8-inch touch screen is completely free from the constraints of the computer.

    2. Brand new furnace structure, can be equipped with a variety of refrigeration devices.

    3. USB communication interface, strong versatility, reliable and uninterrupted communication, and supports self-restoring connection function.

    4. Automatically switch the two-way atmosphere flow, with fast switching speed and short stabilization time. At the same time, a protective gas input is added.

    5. The software is simple and easy to operate.

     