Display: | Liquid-crystal Display | Temperature Control Accuracy: | 0.1℃ |
---|---|---|---|
Temperature Control Range: | Room Temperature + 10℃ -250℃ (300℃ Optional) | Speed: | 0.1 - 200, 58 Rates |
Repetitive Error: | ±1% (Newtonian Liquid) | Test Error: | ±2% (Newtonian Liquid) |
The high-temperature rotating viscometer is used as a coaxial method center structure, using a small amount of sample adapter, each test the sample volume required is very small, and the temperature control is rapid and accurate. Full range, each block linearity all through the PC interface.Use the high temperature standard viscosity solution with different viscosity to ensure that the instrument is available
High precision and repeatability. The measurement range is wide and suitable heat melt glue, asphalt, and polyethylene wax are solid at room temperature
Main Features:
1. The measurement data is directly displayed on the LCD screen, without secondary calculation, and supports Chinese / English exchange display;
2. Adopt micro-computer drive technology, imported stepping motor, the speed is accurate, stable and reliable;
3. The viscosity display resolution is accurate to 0.1% of the full range;
4. With the function of timing measurement, it is very practical for detecting non-Newtonian liquids;
5. With the automatic scanning function, the instrument can automatically recommend the appropriate combination of rotor and rotation speed;
6. It can automatically display the maximum viscosity range of the selected combination of energy measurement;
7. Temperature control range: room temperature-250℃, optional 300℃ heating furnace;
8. With a printing interface, you can directly connect to the micro printer, print all kinds of data, you need to choose a printer;
9. With the interface connected to the computer, you can connect to the computer;
10, support a variety of unit conversion display, viscosity Pa.s/mPa.s/cP/P, temperature ℃ / ℉;
11. Support three kinds of measurement end conditions setting: time, temperature, torque, to meet the requirements of different customers;
12. Support 37 or 58 kinds of speed, improve the test accuracy;
Technical parameter:
model | LV-SSR-H | RV-SSR-H | HA-SSR-H | HB-SSR-H | |||
display | liquid-crystal display | ||||||
speed (r/min) |
0.3 - 100, 37 Rates 0.3,0.5,0.6,1,1.5,2,2.5,3,4,5,6,7,8,9,10,12,14,15,16,18,20,25,30,35,40,45,50,55,60,65,70,75,80,85,90,95,100RPM |
||||||
rotor |
0 rotor(apolegamy)18,25,31,34 rotor (standard configuration ) |
0 rotor(apolegamy) 21,27,28,29 rotor(standard configuration) |
|||||
measuring range mPa.s |
0 rotor:1-1K 18 rotor:3-10K 25 rotor:480-1.6M 31 rotor:30-100K 34 rotor:60-200K |
6.4 - 3.3M 0 rotor:6.4-1K 21 rotor:50-167K 27 rotor:250-834K 28 rotor:500-1.7M 29 rotor:1K-3.3M |
12.8 – 6.6M 21 rotor:100-333K 27 rotor:500-1.7M 28 rotor:1K-3.3M 29 rotor:2K-6.6M |
51.2 – 16M 21 rotor:400-1.3M 27 rotor:2K-6.7M 28 rotor:4K-13.3M 29 rotor:8K-26.6M |
|||
Note: K=1000; M=1,000,000 | |||||||
Sample volume |
0 rotor:21ml 18 rotor:7ml 25 rotor:9ml 31 rotor:10.5ml 34 rotor:11ml |
0 rotor:21ml 27 rotor:11.3ml 28 rotor:12.6ml 29 rotor:11.5ml |
|||||
test error | ±2% (Newtonian liquid) | ||||||
repetitive error | ±1% (Newtonian liquid) | ||||||
Temperature control range | Room temperature + 10℃ -250℃ (300℃ optional) | ||||||
Temperature control accuracy | 0.1℃ | ||||||
data interface |
have
|
model | LV-SSR--2H | RV-SSR-2H | HA-SSR-2H | HB-SSR-2H | |||
display | liquid-crystal display | ||||||
speed (r/min) |
0.1 - 200, 58 Rates 0.1,0.3,0.5,0.6,1,1.5,2,2.5,3,4,5,6,7,8,9,10,12,14,15,16,18,20,25,30,35,40,45,50,55,60,65,70,75,80,85,90,95,100,105,110,115,120,125,130,135,140,145,150,155,160,165,170,175,180,185,190,195,200RPM |
||||||
rotor |
0 rotor(apolegamy)18,25,31,34 rotor (standard configuration) |
0 rotor(apolegamy) 21,27,28,29 rotor(standard configuration) |
|||||
measuring range mPa.s |
1 - 1.6M 0 rotor:1-1K 18 rotor:1.5-30K 25 rotor:240-4.8M 31 rotor:15-300K 34 rotor:30-600K |
3.2 - 3.3M 0 rotor:3.2-1K 21 rotor:25-500K 27 rotor:125-2.5M 28 rotor:250-5M 29 rotor:500-10M |
6.4 – 6.6M 21 rotor:50-1M 27 rotor:250-5M 28 rotor:500-10M 29 rotor:1K-20M |
25.6 – 16M 21 rotor:200-4M 27 rotor:1K-20M 28 rotor:2K-40M 29 rotor:4K-80M |
|||
Note: K=1000; M=1,000,000 | |||||||
Sample volume |
0 rotor:21ml 18 rotor:7ml 25 rotor:9ml 31 rotor:10.5ml 34 rotor:11ml |
0 rotor:21ml 27 rotor:11.3ml 28 rotor:12.6ml 29 rotor:11.5ml |
|||||
test error | ±2% (Newtonian liquid) | ||||||
repetitive error | ±1% (Newtonian liquid) | ||||||
Temperature control range | Room temperature + 10℃ -250℃ (300℃ optional) | ||||||
Temperature control accuracy | 0.1℃ | ||||||
data interface |
have
|
Note: Our company also has a number of high-temperature viscosity meters (bottom right), with a maximum range of 80 million and optional data software to display the rheological curve of shear rate and viscosity
Standard layout:
main engine | 1 | Rotor |
18,25,31,34 or 21,27,28,29 |
Sheng sample tube | 2 Pcs | operating instruction | 1 |
temperature regulating device | 1 | furnace | 1 |
tool | 1 Pcs | gauge plate | 1 Pcs |
Put the sample tube shelf | 1 | Insulation cover | 1 |